Skip to content

How to flash and update the kit firmware

How to flash and update the kit firmware
November 19, 2026

This guide is for the person with technical knowledge who prepares the kit’s access points. It covers the first flash of the emergency firmware over the TP-Link factory firmware and the updates afterwards. What comes configured in the firmware is in What comes configured in the kit firmware.

A wrong flash can leave the access point not working. Never cut the power during flashing, use only the image made for your model and do not flash if the checksum does not match. On these models there is no automatic return to the previous version: recovery requires opening the device and using a serial cable.

Who does it: person with technical knowledge (level 3 on the stickers) · Time: about 30 minutes per access point for the first flash

Round table with laptops, white and orange access points, network cables and a radio, during equipment preparation
Flashing is done on the workbench, well in advance, never in the field.

Before you start

  • Check the model and revision on the device label. The kit uses the EAP225-Outdoor v3. Units of revision v3.20 with factory firmware 5.2.4 do not yet accept the change, according to the OpenWrt wiki. These units come in a green box and have “Omada” on the device.
  • Set aside a laptop with a network port, the PoE injector, two network cables and a stable power socket.
  • Download the images from the address given by the team that delivered the kit. For each model, there are three files:
FileWhat it is for
Image ending in factory.binFirst flash, over the TP-Link factory firmware
Image ending in sysupgrade.binUpdating a point that already has the kit firmware
sha256sumsList of checksums, to check the files

1. Check the checksum

The checksum guarantees that the downloaded file is exactly the one published. If it does not match, the file may be corrupted or tampered with. Do not flash it.

SystemCommand, in the folder with the files
Linuxsha256sum --ignore-missing -c sha256sums
macOSshasum -a 256 nome-da-imagem.bin and compare with the line in the sha256sums file
Windowscertutil -hashfile nome-da-imagem.bin SHA256 and compare with the line in the sha256sums file

2. Do the first flash on the EAP225-Outdoor

These steps follow the OpenWrt wiki for the EAP225-Outdoor v3.

  1. Update the factory firmware, if needed. The wiki recommends starting from a safe version: old versions can brick the device during the change. If the device is on version 5.1.1, first update it to 5.1.11 through the TP-Link interface.
  2. Access the TP-Link interface. Connect the point to the injector and the laptop to the injector. The access address is not always the same, so check where to find it:
    • Quick installation guide that comes in the device’s box: it shows how to open the interface in the browser.
    • List of connected devices on the network’s router, if there is a router handing out addresses.
    • TP-Link discovery program (EAP Discovery), which looks for the access points on the network and shows the address of each one.
    • OpenWrt wiki for the EAP225, which gives the default address when there is no router on the network.
  3. Enable SSH in the TP-Link interface settings.
  4. Log in through the terminal. The factory firmware uses old algorithms, so the command is long. Replace ADDRESS-OF-THE-POINT with the address found in step 2:
ssh -oPubkeyAcceptedAlgorithms=+ssh-rsa -o HostKeyAlgorithms=ssh-rsa -oKexAlgorithms=+diffie-hellman-group1-sha1 admin@ADDRESS-OF-THE-POINT
  1. Unlock the change. In the terminal, run cliclientd stopcs. Without this step, the interface rejects the image with a file error.
  2. Upload the image. In the TP-Link interface, on the firmware update screen, upload the factory.bin file. The file name must be shorter than 63 characters: rename it if needed.
  3. Wait. The device flashes and restarts on its own. Do not cut the power during this time.

3. Access the point with the new firmware

  1. Connect the phone or laptop to the emergency network that appears.
  2. Go to thisnode.info, LiMe-App.
  3. Set the administration password: in the menu, go to Network configuration. LibreMesh comes without a password.

4. Check that everything is right

CheckWhere
Firmware versionLiMe-App status screen or LuCI › Status › Overview
Wi-Fi networksThe phone’s list of networks: the emergency network and the network with the point’s name
Notice pageConnect the phone and see the page open on its own
MeshWith two or more points switched on, see the neighbours in LiMe-App

From the terminal, the command ssh root@thisnode.info followed by cat /etc/openwrt_release shows the installed version.

5. Update later

To update a point that already has the kit firmware, always use the sysupgrade.bin image. The factory image is only for the first flash and must never be uploaded through LuCI or LiMe-App. Update all the kit’s points to the same version.

Through LiMe-App

  1. Go to thisnode.info and open the Firmware screen.
  2. Choose the option to upload an image from your device and select the sysupgrade.bin file.
  3. LiMe-App checks whether the image is right for the point before flashing.
  4. Confirm and wait for the point to restart.

LiMe-App always keeps the LibreMesh configuration. On these models, it warns that there is no automatic return to the previous version if something goes wrong.

Through LuCI

  1. Go to thisnode.info/cgi-bin/luci and log in with the administration password.
  2. Go to System › Backup / Flash Firmware.
  3. Under Flash new firmware image, choose the sysupgrade.bin file.
  4. Decide whether to keep the settings. The OpenWrt documentation recommends keeping them only for small updates; between very different versions, flash without keeping them.
  5. Check the checksum shown on screen before confirming.
  6. Wait for the point to restart.

Through the terminal

For those who already use the terminal:

scp -O nome-da-imagem-sysupgrade.bin root@thisnode.info:/tmp/
ssh root@thisnode.info "sha256sum /tmp/nome-da-imagem-sysupgrade.bin"
ssh root@thisnode.info "sysupgrade -v /tmp/nome-da-imagem-sysupgrade.bin"
  • The image must be in the access point’s /tmp folder.
  • Check the checksum on the point itself, before flashing.
  • With no extra option, sysupgrade keeps the settings. With -n, it flashes without keeping them.
  • It is normal for the terminal connection to drop during flashing. If the point does not answer after 5 minutes, switch it off and on again.

6. After updating

  1. Repeat the check from step 4 on each point.
  2. If the mesh behaves strangely after several flashes in a row, restart all the points before concluding that there is a fault.
  3. Write down the flashed version and the date on the kit’s record sheet.

See also

Sources

Last updated on